This instrument, through its meticulously designed and optimized sample introduction system, significantly improves the accuracy and repeatability of sample analysis. Furthermore, its circuitry has undergone a comprehensive upgrade, not only greatly accelerating computational speed and data processing capabilities but also significantly enhancing the instrument’s stability and durability, creating a more robust and efficient analytical platform for users. This enables the instrument to maintain long-term stable operation in various application environments, easily meeting users’ diverse daily testing needs.

$ 0.00

Available on backorder

Product Details

BK-GC900A Gas Chromatograph – Technical Parameters

Oven

  • Model: BK-GC900A
  • Temperature Range: RT+5–450°C
  • Temperature Control Accuracy: 0.01°C
  • Temperature Program: ≥20 levels (expandable)
  • Maximum Temperature Heating Rate: 120°C/min
  • Temperature Control System: An 8-channel independent temperature control system with automatic temperature protection function

Selectable Detector Types

Flame Ionization Detector (FID)

  • Operating Temperature: 450°C
  • Detection Limit: ≤5.0×10⁻¹²g/s (n-hexadecane/isooctane)
  • Baseline Drift (30 min): ≤2×10⁻¹⁴A
  • Baseline Noise: ≤2×10⁻¹⁵A
  • Dynamic Linear Range: ≥10⁷
  • Automatic Ignition Function

Thermal Conductivity Detector (TCD)

  • Sensitivity: ≥8,000mV·mL/mg
  • Baseline Drift (30 min): ≤0.2mV
  • Baseline Noise: ≤0.05mV
  • Dynamic Linear Range: ≥10⁵
  • Safety Protection: Gas bridging current protection function

Selectable Sample Injection Method

  • Compatible with standard and inert flow path split/splitless capillary injection, septum purge packed column injection, cold column injection, programmable temperature vaporization injection ports, valve injection system, headspace injection systems, thermal desorption injection systems, etc.

Standard Accessories

  • FID detector, general chromatography workstation software, capillary sampler, startup toolkit

Optional Accessories

  • Sample injection system, TCD detector, audit chromatography workstation software, chromatographic column, nickel catalytic converter, liquid autosampler, headspace sampler

Power Supply

  • AC220V, 50/60Hz

Product Size (W×D×H)

  • 550×580×480mm

Net Weight

  • 45kg

Packing Size (W×D×H)

  • 750×710×750mm

Gross Weight

  • 57kg

Remark: 2 different types of detectors can be installed simultaneously.