This instrument perfectly blends cutting-edge technology with user-friendly design, marking a significant advancement in the field of analytical instruments. Equipped with an industry-leading technology platform and a self-developed advanced data processing system, it not only achieves superior performance but also significantly enhances ease of use, ushering in a new era of intelligent analysis for users and contributing technological power to the development and innovation of related industries.

$ 0.00

Available on backorder

Product Details

BK-GC908 Gas Chromatograph – Technical Parameters

Oven

  • Model: BK-GC908
  • Temperature Range: RT+2–450°C
  • Temperature Control Accuracy: 0.01°C
  • Temperature Program: ≥99 levels, 100 platform (expandable)
  • Maximum Temperature Heating Rate: 250°C/min
  • Temperature Control System: An 8-channel independent temperature control system with automatic temperature protection function

Selectable Detector Types

Flame Ionization Detector (FID)

  • Operating Temperature: 450°C
  • Detection Limit: ≤1.1pg C/s (n-hexadecane)
  • Baseline Drift (30 min): ≤2×10⁻¹⁴A
  • Baseline Noise: ≤2×10⁻¹⁵A
  • Dynamic Linear Range: ≥10⁷
  • Automatic Ignition Function

Thermal Conductivity Detector (TCD)

  • Sensitivity: 10,000 mV·mL/mg
  • Baseline Drift (30 min): ≤0.2mV
  • Baseline Noise: ≤0.05mV
  • Dynamic Linear Range: ≥10⁵
  • Safety Protection: Gas bridging current protection function

Flame Photometric Detector (FPD)

  • Maximum Operating Temperature: 450°C
  • Limit of Detection: P ≤0.8pg/s (methyl parathion)
  • Selectivity: S ≥8pg/s (methyl parathion)
  • Dynamic Linear Range: ≥10³
  • Equipped with automatic ignition function

Electron Capture Detector (ECD)

  • Radioactive Source: ⁶³Ni
  • Maximum Operating Temperature: 400°C
  • Limit of Detection: ≤1.0×10⁻¹⁴g/mL (γ-666)
  • Dynamic Linear Range: ≥10⁴

Nitrogen-Phosphorus Detector (NPD)

  • Maximum Operating Temperature: 400°C
  • Limit of Detection: N ≤1×10⁻¹³g/s (N in azobenzene); P ≤5×10⁻¹⁴g/s (P in malathion)
  • Dynamic Linear Range: ≥10⁴

Selectable Sample Injection Method

  • Compatible with standard and inert flow path split/splitless capillary injection, septum purge packed column injection, cold column injection, programmable temperature vaporization injection ports, valve injection system, headspace injection systems, thermal desorption injection systems, etc.

Standard Accessories

  • FID detector, general chromatography workstation software, capillary sampler, startup toolkit

Optional Accessories

  • Sample injection system, TCD, ECD, FPD and NPD detector, audit chromatography workstation software, chromatographic column, nickel catalytic converter, liquid autosampler, headspace sampler

Power Supply

  • AC220V, 50/60Hz

Product Size (W×D×H)

  • 610×530×500mm

Net Weight

  • 50kg

Packing Size (W×D×H)

  • 800×640×750mm

Gross Weight

  • 63kg

Remark: 2 different types of detectors can be installed simultaneously.