Product successfully added to the Quote List
Gas Chromatograph BK-GC906
This instrument perfectly blends cutting-edge technology with user-friendly design, marking a significant advancement in the field of analytical instruments. Equipped with an industry-leading technology platform and a self-developed advanced data processing system, it not only achieves superior performance but also significantly enhances ease of use, ushering in a new era of intelligent analysis for users and contributing technological power to the development and innovation of related industries.
Available on backorder
Product Details
BK-GC908 Gas Chromatograph – Technical Parameters
Oven
- Model: BK-GC908
- Temperature Range: RT+2–450°C
- Temperature Control Accuracy: 0.01°C
- Temperature Program: ≥99 levels, 100 platform (expandable)
- Maximum Temperature Heating Rate: 250°C/min
- Temperature Control System: An 8-channel independent temperature control system with automatic temperature protection function
Selectable Detector Types
Flame Ionization Detector (FID)
- Operating Temperature: 450°C
- Detection Limit: ≤1.1pg C/s (n-hexadecane)
- Baseline Drift (30 min): ≤2×10⁻¹⁴A
- Baseline Noise: ≤2×10⁻¹⁵A
- Dynamic Linear Range: ≥10⁷
- Automatic Ignition Function
Thermal Conductivity Detector (TCD)
- Sensitivity: 10,000 mV·mL/mg
- Baseline Drift (30 min): ≤0.2mV
- Baseline Noise: ≤0.05mV
- Dynamic Linear Range: ≥10⁵
- Safety Protection: Gas bridging current protection function
Flame Photometric Detector (FPD)
- Maximum Operating Temperature: 450°C
- Limit of Detection: P ≤0.8pg/s (methyl parathion)
- Selectivity: S ≥8pg/s (methyl parathion)
- Dynamic Linear Range: ≥10³
- Equipped with automatic ignition function
Electron Capture Detector (ECD)
- Radioactive Source: ⁶³Ni
- Maximum Operating Temperature: 400°C
- Limit of Detection: ≤1.0×10⁻¹⁴g/mL (γ-666)
- Dynamic Linear Range: ≥10⁴
Nitrogen-Phosphorus Detector (NPD)
- Maximum Operating Temperature: 400°C
- Limit of Detection: N ≤1×10⁻¹³g/s (N in azobenzene); P ≤5×10⁻¹⁴g/s (P in malathion)
- Dynamic Linear Range: ≥10⁴
Selectable Sample Injection Method
- Compatible with standard and inert flow path split/splitless capillary injection, septum purge packed column injection, cold column injection, programmable temperature vaporization injection ports, valve injection system, headspace injection systems, thermal desorption injection systems, etc.
Standard Accessories
- FID detector, general chromatography workstation software, capillary sampler, startup toolkit
Optional Accessories
- Sample injection system, TCD, ECD, FPD and NPD detector, audit chromatography workstation software, chromatographic column, nickel catalytic converter, liquid autosampler, headspace sampler
Power Supply
- AC220V, 50/60Hz
Product Size (W×D×H)
- 610×530×500mm
Net Weight
- 50kg
Packing Size (W×D×H)
- 800×640×750mm
Gross Weight
- 63kg
Remark: 2 different types of detectors can be installed simultaneously.
Related Products
-
7A-23D Electric Suction Apparatus
$ 0.00 -
Alcoholometer – Type Richter + Tralles, 0-100 w/o, 265 mm Length
$ 0.00 -
Alcoholometer, 0-100 w/o, 265 mm Length
$ 0.00 -
Alcoholometer, Gay-Lussac, 0-100 %vol Gl, 265 mm Length
$ 0.00 -
Aluminium pycnometer-densimeter
$ 0.00 -
Ammeter Dual Range 0-5/10A Analogue
$ 0.00